Flamebuster HRC2 inherent hi-vis reflective coverall
The Flamebuster HRC2 inherent hi-vis reflective coverall (FCT005A) puts inherent flame resistance and day and night FR reflective tape in one garment, with gas detector loops at the shoulder and cargo pockets at the hips and thighs.
Key takeaways
- Flame resistance in the FCT005A is inherent to the fibre rather than a surface coating, so it is not designed to wash out.
- FR perforated reflective tape rated for day and night use gives the coverall its low light visibility.
- Gas detector loops sit at the shoulder for a monitor, alongside angled front pockets, hip and thigh cargo pockets and a left chest pocket with a pen divide.
- Flamebuster does not state a protection class or a certified standard on this listing, so confirm both before a regulated job.
| Spec | Flamebuster FCT005A | What to check |
|---|---|---|
| Flame resistance | Inherent (HRC2 inherent, hi vis reflective) | Match the class to your site risk assessment |
| Reflective tape | FR perforated reflective tape, day and night use | Check the tape for damage each shift |
| Gas monitor mounting | Gas detector loops at shoulder | Confirm your monitor clip suits the loop |
| Pockets | Angled front, hip and thigh cargo, left chest | Check the chest pocket pen divide |
| Front closure | Concealed placket, two way zipper, press studs | Check the zipper runs and studs sit flat |
| Product code | FCT005A | Quote this code when you order |
What is the Flamebuster HRC2 inherent hi-vis reflective coverall?
The Flamebuster HRC2 (FCT005A) is a one piece flame resistant coverall for crews who need hi vis cover and FR protection in the same garment. Flame resistance is inherent, so it comes from the fibre itself rather than a coating, and FR perforated reflective tape carries visibility for day and night work.
The Flamebuster HRC2 is a one piece flame resistant coverall built for crews who need hi vis cover and FR protection in the same garment. The flame resistance is inherent, so it comes from the fibre itself rather than a coating that can wear off over time. That matters on jobs where a worker lives in the same overall shift after shift.
The detailing suits a full day in the garment. There is a concealed placket over a two way zipper, backed up with heat resistant press studs, plus full gusset sleeves that give your arms room when you reach overhead. Pockets sit where you would want them: angled fronts, cargo pockets at the hips and thighs, and a left chest pocket with a pen divide. Gas detector loops sit at the shoulder so a monitor can clip where it is meant to.
It carries FR perforated reflective tape rated for day and night use, and the build uses twin needle stitching with reinforced stress points so the seams hold up to repeated wear. If you want to read the full listing or check sizing before you order, the Done Right Safety product page has the detail.
Key features
- Inherent flame resistance built into the fibre rather than a surface coating
- Concealed placket over a two way zipper, with heat resistant button down press studs
- FR perforated reflective tape for day and night use
- Full gusset sleeves with concealed heat resistant press studs for arm movement
- Front angled pockets, hip and thigh cargo pockets, plus a left chest pocket with pen divide
- Gas detector loops at the shoulder for clipping a monitor
- Darted knees and twin needle stitching with reinforced stress points
Where it fits
- Oil, gas and petrochemical sites where FR clothing and hi vis are both required
- Electrical and utilities work that calls for flame resistant outerwear
- Heavy industry and maintenance crews carrying gas monitors and a load of small tools
- Day and night shift work where reflective visibility is part of the site rules
Flamebuster HRC2 inherent hi-vis reflective coverall specifications
| Specification | Detail |
|---|---|
| Brand | Flamebuster |
| Product code | FCT005A |
| Category | Hi-Vis Workwear / Overalls/Coveralls |
| Product type | Coverall (one piece) |
| Flame resistance | Inherent (HRC2 inherent, hi vis reflective) |
| Front closure | Concealed placket with two way zipper and button down heat resistant press studs |
| Sleeves | Full gusset sleeves with concealed heat resistant press stud |
| Front pockets | Two front pockets with concealed heat resistant press studs |
| Additional pockets | Front angled pockets; cargo pockets at hips and thighs; left chest pocket with pen divide |
| Gas monitor mounting | Gas detector loops at shoulder |
| Reflective tape | FR perforated reflective tape |
| Visibility use | Day and night use |
| Knees | Darted knees for better movement |
| Construction | Twin needle stitching with reinforced stress points |
| Product name | FLAMEBUSTER HRC2 INHERENT HI VIS REFLECTIVE COVERALL |
| Where to buy | Done Right Safety, donerightsafety.com.au |
How do you fit and care for the Flamebuster HRC2 coverall?
Site risk decides first: an inherent FR hi vis coverall suits work with an arc flash or flash fire risk where you also need to be seen. Reach overhead, squat and kneel before a shift to test movement, then follow the garment care label, because FR clothing has specific washing requirements.
Working out if it suits the job
Start with what your site demands. If the work has an arc flash or flash fire risk and you also need to be seen, an inherent FR hi vis coverall like this one covers both jobs in a single garment. Inherent FR means the protection is part of the fibre, so it does not wash out the way a treated finish can. The exact protection class and any standards the garment is certified to should be confirmed on the Done Right Safety product page or the manufacturer datasheet, since those details are not listed here.
Think about what you carry. The hip and thigh cargo pockets, angled front pockets and the pen divide on the chest pocket suit a worker who keeps tools, a phone and a notebook on them. The shoulder gas detector loops are worth checking against the monitor you actually use, so the clip sits where it should.
Checking fit before a shift
With a one piece coverall, range of movement is the thing to test. Reach overhead, squat and kneel in it. The full gusset sleeves and darted knees are built to give you that movement, but you still want enough room across the shoulders and seat so the garment is not pulling when you climb or crouch. Make sure the two way zipper runs freely and the press studs over the placket all sit flat.
Care and inspection
Follow the care instructions on the garment label, since FR clothing can have specific washing requirements to keep the fabric performing. Before each shift, look over the reflective tape, the seams at the reinforced stress points, and the stud closures. Retire the coverall if the fabric is torn, heavily contaminated with flammable material, or if the FR performance is in any doubt. Confirm care and service life details on the product page or datasheet.
How does the Flamebuster HRC2 compare with other FR coveralls?
Fabric and use case split these four FR coveralls. The Flamebuster leans into pocket layout and gas monitor loops. The Bisley APEX and the Force 360 Defender build in ways to stay cooler, while the DNC Patron Saint is the heaviest fabric and lists ISO 11612:2008 on its page.
The four coveralls below are like for like, same type FR coveralls stocked by Done Right Safety, so the comparison is a genuine head to head rather than a swap for an adjacent garment. The Flamebuster is in the first column.
The real split here is fabric and use case. The Flamebuster leans into pocket layout and gas monitor loops, which suits a worker who lives in the suit and carries gear. If heat stress is your main problem, the Bisley APEX and the Force 360 Defender both build in ways to stay cooler, the APEX through mesh ventilation and a combination fabric weight, the Defender through a lightweight breathable triple layer.
If a listed protection standard is the deciding factor, the DNC Patron Saint and the Force 360 Defender both name one on their listings (ISO 11612:2008 and EN 14116 respectively), while the Flamebuster's standards are not stated in this listing and should be confirmed on its product page. The DNC is also the heaviest fabric of the four, which tends to mean more durable but warmer.
| Feature | Flamebuster (FCT005A) | Bisley APEX (BC8477T) | DNC Patron Saint (3425) | Force 360 Defender (CFPR183) |
|---|---|---|---|---|
| Brand | Flamebuster | Bisley | DNC | Force 360 |
| Flame resistance | Inherent FR | Inherent FR ripstop fabric | FR cotton drill | FR coating on SMS material |
| Stated standard | Confirm on product page | Not specified | ISO 11612:2008 | EN 14116 |
| Fabric weight | Not specified | 185gsm upper, 240gsm lower | 311gsm | 55gsm |
| Reflective tape | FR perforated reflective tape, day and night | Perforated FR reflective taped hoop pattern | Hi vis two tone (tape not detailed) | Not specified |
| Ventilation / heat | Not specified | Underarm and vertical back mesh ventilation | Not specified | Breathable triple layer SMS for hot, humid work |
| Closure | Concealed placket, two way zip, heat resistant press studs | Concealed plastic press snap front | Press studs and gusset sleeves | Two way zipper, unzips at neck or waist |
| Best for | FR hi vis cover with lots of pockets and gas monitor loops | FR work in the heat, with built in ventilation | Heavier FR drill with a listed thermal standard | Lightweight FR coverall for hot, humid sites |
| Feature | Flamebuster (FCT005A) | Bisley APEX (BC8477T) | DNC Patron Saint (3425) | Force 360 Defender (CFPR183) |
|---|---|---|---|---|
| Brand | Flamebuster | Bisley | DNC | Force 360 |
| Flame resistance | Inherent FR | Inherent FR ripstop fabric | FR cotton drill | FR coating on SMS material |
| Stated standard | Confirm on product page | Not specified | ISO 11612:2008 | EN 14116 |
| Fabric weight | Not specified | 185gsm upper, 240gsm lower | 311gsm | 55gsm |
| Reflective tape | FR perforated reflective tape, day and night | Perforated FR reflective taped hoop pattern | Hi vis two tone (tape not detailed) | Not specified |
| Ventilation / heat | Not specified | Underarm and vertical back mesh ventilation | Not specified | Breathable triple layer SMS for hot, humid work |
| Closure | Concealed placket, two way zip, heat resistant press studs | Concealed plastic press snap front | Press studs and gusset sleeves | Two way zipper, unzips at neck or waist |
| Best for | FR hi vis cover with lots of pockets and gas monitor loops | FR work in the heat, with built in ventilation | Heavier FR drill with a listed thermal standard | Lightweight FR coverall for hot, humid sites |
Is the Flamebuster HRC2 coverall worth buying?
Flamebuster covers the practical bases for an FR hi vis coverall: inherent flame resistance, day and night FR reflective tape, a concealed placket closure and a heavy pocket loadout with shoulder gas detector loops. The listing does not state a protection class, certified standard, fabric weight or size range.
As an FR hi vis coverall, the Flamebuster covers the practical bases well. The inherent flame resistance is the headline: protection that is part of the fibre rather than a finish, which is what you want for a garment worn day in, day out. The pocket layout, the gas detector loops at the shoulder, and the reinforced twin needle stitching all point to a coverall meant for real industrial wear rather than light duty.
What is clearly confirmed on the listing: the inherent FR construction, the day and night FR reflective tape, the closure system, and the pocket and gusset detailing. What we cannot confirm from the listing is the specific protection class, any certified standard, the fabric weight, and the size range. Those are the points a buyer with a strict site spec should verify on the Done Right Safety product page or the manufacturer datasheet before committing.
For a crew that needs FR and hi vis in one garment with plenty of storage, this is an easy one to shortlist. Just match the protection level to your site's risk assessment first.
Frequently asked questions
Will the flame resistance wash out over time?
The listing describes the FCT005A as an inherent FR coverall, which means the flame resistance comes from the fibre itself rather than a topical treatment. Inherent FR is not designed to wash out the way a coating can. Always follow the garment care label, as FR clothing often has specific washing requirements.
Does the Flamebuster HRC2 coverall work for day and night shifts?
Yes. The coverall uses FR perforated reflective tape and is listed for day and night use, so it carries the reflective element you need for low light visibility as well as the hi vis base for daytime work. Check the tape for damage before each shift.
Can you clip a gas monitor to the Flamebuster coverall?
Gas detector loops at the shoulder are built into this coverall for mounting a monitor, so the detector sits where it is meant to clip on. Check that the loop suits the clip on your specific gas detector before you order, since clip designs vary between monitors.
What standards does the Flamebuster HRC2 coverall meet?
No standards or protection class are listed for this coverall in the source listing, so no specific rating is claimed here. Confirm any certifications and the FR class on the Done Right Safety product page or the manufacturer datasheet before relying on the garment for a regulated job.
How does the Flamebuster compare to the Force 360 Defender FR coverall?
The Force 360 Defender (CFPR183) is a lightweight FR coverall built around a breathable triple layer SMS material for hot, humid work, and it lists EN 14116 on its page. The Flamebuster is a fully featured industrial coverall, with inherent FR, a heavier pocket loadout and gas monitor loops.
Is there enough room to move in a one piece coverall?
Full gusset sleeves and darted knees are built into the FCT005A to improve range of movement for reaching and crouching. As with any coverall, try it on and test squatting and reaching overhead so you have room across the shoulders and seat before a shift.
Sources
- Flamebuster product listing on donerightsafety.com.au