Done Right SafetyDone Right SafetyHub
Visit the store

Pratt gravity fed portable eyewash unit, 35L

The Pratt SE5000 is a 35 litre gravity fed portable eyewash station for work points where a plumbed water supply cannot be run. Pratt lists it against AS4775 and ANSI Z358.1 and supplies one bottle of SE4764 water preservative with it.

Brand PrattCode SE5000Category Washroom and lunchroom suppliesLast updated 5 June 2026

Key takeaways

  • The Pratt SE5000 holds 35 litres and runs on gravity, so no mains water connection is needed at the point of use.
  • Pratt lists the SE5000 against AS4775 and ANSI Z358.1, the two standards Australian buyers usually specify for emergency eyewash equipment.
  • The polyethylene tank measures 560L x 250W x 360H mm and arrives with one bottle of SE4764 water preservative.
Quick specs
SpecPratt SE5000What to check
Capacity35L gravity fed tankMatch flush volume to the people at risk
Water supplySelf-contained, no plumbing neededConfirm no mains water reaches the hazard
Standards listedAS4775 and ANSI Z358.1Check both match your workplace specification
Dimensions560L x 250W x 360H mmConfirm the bench or stand space fits
MaterialPolyethyleneCheck it survives knocks where it sits
Included1 bottle of SE4764 water preservativeCheck what else the listing supplies

What is the Pratt SE5000 35L portable eyewash station?

The Pratt SE5000 is a 35 litre portable eyewash station that runs on gravity rather than mains pressure, so a site can put emergency flushing right where chemicals are handled without plumbing. Pratt builds the tank from polyethylene, lists the unit against AS4775 and ANSI Z358.1, and supplies one bottle of SE4764 water preservative.

The SE5000 is a 35L portable eyewash station from Pratt, built for sites where you cannot run a plumbed water supply to the spot that needs eye-flushing. It is gravity fed, so it works off the head of water in the tank rather than mains pressure. That makes it a sensible choice for remote work areas, temporary setups, or any bay where a permanent fixture is not practical.

The unit holds 35 litres and is made from polyethylene, so it is light enough to move and resistant to the kind of knocks a portable unit cops on site. It ships with one bottle of SE4764 water preservative, which keeps the standing water usable between refills. Pratt lists the station against AS4775 and ANSI Z358.1, the two standards most Australian buyers look for when specifying emergency eyewash equipment.

If you are weighing this up for a workshop or a job site, you can view the full listing on Done Right Safety to check the current details before you order.

Key features

  • Portable gravity-fed eyewash station with a 35 litre capacity
  • Works where plumbed water is not available, so no mains connection is required
  • Polyethylene construction for a light, knock-resistant portable unit
  • Listed against Australian Standard AS4775 and ANSI Z358.1
  • Supplied with one bottle of SE4764 water preservative to keep the stored water usable
  • Compact footprint at 560L x 250W x 360H mm
  • Aimed at providing initial first aid flushing for chemical splashes and eye injuries

Where it fits

  • Remote or temporary work areas where you cannot plumb in a fixed eyewash
  • Workshops, stores, and lunchroom or washroom areas that handle chemicals
  • Job sites that need an eyewash point close to the task rather than at a wall fitting
  • Backup or supplementary flushing where a single fixed station does not cover the whole work area

Pratt gravity fed portable eyewash unit, 35L specifications

Pratt gravity fed portable eyewash unit, 35L specifications
SpecificationDetail
BrandPratt
Product codeSE5000
CategoryWorkplace Safety / Washroom/Lunchroom
Product typeEmergency shower and eyewash
Standards or ratings listedAS4775 and ANSI Z358.1
Measurements or capacities listed35L capacity; 560 mm length dimension
Capacity35L
TypePortable, gravity fed
Dimensions560L x 250W x 360H mm
Material of constructionPolyethylene
Included1 bottle of SE4764 water preservative
Water supplySelf-contained, suited to sites without plumbed water
Intended useInitial first aid flushing for chemical burns and eye injuries
Product namePRATT EYE WASH - GRAVITY FED PORTABLE UNIT 35L
Where to buyDone Right Safety, donerightsafety.com.au

How do you set up and maintain the Pratt SE5000 eyewash?

Fill the Pratt SE5000 with clean potable water, add the supplied SE4764 preservative, sit the unit level near the hazard and check the nozzles are clear before signing it off as ready. Set a routine to check the fill level, change the water, top up the preservative and keep the nozzles clean.

Working out if a portable gravity-fed unit suits your site

The first question is whether you can plumb water to where you need it. If you can, a fixed plumbed station is usually the simpler long-term answer. If you cannot, a portable gravity-fed unit like this one becomes the practical option. The 35L size suits a single work point or a small team. If you expect to cover a larger area or more people, step up to a higher-capacity unit so the available flush volume matches the risk.

Think about where the unit will live. The 560 x 250 x 360 mm footprint is small enough to sit on a bench, a stand, or a dedicated shelf near the hazard. Position it so anyone working with chemicals can reach it quickly without hunting for it, since the value of an eyewash is in how fast someone can get to it after a splash.

Setting up and filling

Fill the tank with clean potable water and add the supplied SE4764 water preservative. The preservative is there to keep the stored water in usable condition between changes, which matters for a self-contained unit that is not being constantly refreshed by mains flow. Make sure the unit sits level and the nozzles are clear before you sign it off as ready.

Inspection and water changes

Standing water needs a routine. Set a schedule to check the fill level, change the water, and top up the preservative so the station is always ready to use. Keep the nozzles clean and free of dust. Confirm the inspection and water-change intervals against the product documentation and your own site procedures, and check that the unit's compliance with AS4775 and ANSI Z358.1 still meets what your workplace has specified.

Should you buy the 35L SE5000 or the 55L SE5050?

Choose the 35L SE5000 for a single work point with no plumbed water, and step up to the 55L SE5050 when a larger area or more people need flush volume. The SE590A adds face and body washing with a drench hose, while the plumbed SE546 pedestal unit suits a permanent fitting.

All four units here are emergency eyewash or shower products from Pratt, so this is a same-type comparison. The real differences come down to capacity, how the unit is supplied with water, and whether it is portable or a fixed fitting.

If your only constraint is that you cannot run plumbed water, the choice is mostly about size and what you need to flush. The SE5000 covers a single point well, and the SE5050 is the same idea with 55L on hand when you want more flush volume or have more people to cover. The SE590A moves up to eye, face and body washing with a drench hose, and it uses a compressed-air pressurised tank rather than gravity, so it suits splashes that go beyond the eyes.

The SE546 is the odd one out here: it is a fixed pedestal unit that needs a plumbed supply, and it is built for eye hazards rather than full face or body flushing. Pick it only when you have water at the location and want a permanent fitting rather than a unit you can pick up and move.

FeaturePratt (SE5000)Pratt (SE5050)Pratt (SE590A)Pratt (SE546)
BrandPrattPrattPrattPratt
FormatPortable eyewash stationPortable eyewash stationPortable eye and body wash stationPedestal mounted eyewash with bowl
Capacity35L55L45LNot specified (plumbed supply)
Water supplyGravity fedGravity fedStainless tank pressurised with compressed airPlumbed, hand and foot operated
Standard listedAS4775 and ANSI Z358.1AS4775 and ANSI Z358.1Not specifiedAS4775
NozzlesSee product pageSee product pageTwin soft stream eye wash nozzles with dust caps, plus drench hoseDual aerated eye wash nozzle
Best forSingle point where no plumbed water is availableSame setup as the 35L but more flush volume for larger areasEye, face and body flush where you also want a drench hosePermanent point with plumbed water; eye hazards rather than face or body
Pratt gravity fed portable eyewash unit, 35L against similar Done Right Safety products
FeaturePratt (SE5000)Pratt (SE5050)Pratt (SE590A)Pratt (SE546)
BrandPrattPrattPrattPratt
FormatPortable eyewash stationPortable eyewash stationPortable eye and body wash stationPedestal mounted eyewash with bowl
Capacity35L55L45LNot specified (plumbed supply)
Water supplyGravity fedGravity fedStainless tank pressurised with compressed airPlumbed, hand and foot operated
Standard listedAS4775 and ANSI Z358.1AS4775 and ANSI Z358.1Not specifiedAS4775
NozzlesSee product pageSee product pageTwin soft stream eye wash nozzles with dust caps, plus drench hoseDual aerated eye wash nozzle
Best forSingle point where no plumbed water is availableSame setup as the 35L but more flush volume for larger areasEye, face and body flush where you also want a drench hosePermanent point with plumbed water; eye hazards rather than face or body

Is the Pratt SE5000 35L eyewash worth buying?

Buyers who cannot run plumbed water to the hazard get a straightforward unit here. The gravity feed keeps it simple, the polyethylene body copes with being moved around, and the SE4764 preservative is included from day one. Confirm nozzle detail, flush duration at 35L and the water-change schedule before ordering.

For a site that cannot run plumbed water to the hazard, this Pratt unit does the core job in a straightforward way. The gravity-fed design keeps it simple, the polyethylene body is practical for something that gets moved around, and including the SE4764 preservative means you can fill it and keep the water usable from day one. The 35L size is honest about what it is: a single-point station rather than a unit meant to flush a whole crew.

What is confirmed on the listing is the capacity, the portable gravity-fed format, the polyethylene construction, the dimensions, the included preservative, and the AS4775 and ANSI Z358.1 listing. Those are the facts to lean on when you specify it.

What you should verify on the product page or datasheet before you commit: nozzle detail, flush duration at 35L for your situation, the recommended water-change and inspection schedule, and that the listed standards match exactly what your workplace requires. If you need more flush volume or face and body coverage, look at the larger or pressurised units in the same Pratt range rather than stretching this one past what it is built for.

Frequently asked questions

Does the Pratt SE5000 eyewash need a plumbed water connection?

No. The Pratt SE5000 is a self-contained portable unit that works off gravity from the water held in its tank, so it is made for spots where you cannot run plumbed water. You fill it yourself, add the supplied preservative and keep the level topped up.

Is 35 litres enough capacity for a portable eyewash station?

The tank holds 35 litres, which suits a single work point or a small team rather than a whole crew. Sites covering a larger area or more people should step up to a higher-capacity unit such as the 55L SE5050, so the available flush volume matches the risk.

What is the SE4764 water preservative for?

One bottle of SE4764 water preservative ships with the unit, and its job is keeping the stored water in usable condition between changes. Water sitting in a self-contained tank is not refreshed by mains flow, so the preservative helps maintain it until the next scheduled water change.

What standards is the Pratt SE5000 eyewash listed against?

Pratt lists this station against AS4775 and ANSI Z358.1, the two designations Australian buyers usually look for when specifying emergency eyewash equipment. Confirm on the product page or datasheet that both match what your workplace has specified, and check the intervals your own site procedures require.

How does the SE5000 differ from the 55L Pratt SE5050?

The SE5050 uses the same portable gravity-fed design and carries the same AS4775 and ANSI Z358.1 listing, but holds 55 litres instead of 35. Choose the larger tank when you want more flush volume on hand, or when the area or headcount you are covering grows.

How do you keep a portable eyewash station ready to use?

Set a routine that checks the fill level, changes the water, tops up the SE4764 preservative and keeps the nozzles clean and free of dust. Confirm the recommended inspection and water-change intervals against the product documentation and your own site procedures so the station is always ready.

PRATT eye wash - Gravity fed portable unit 35L
Product code SE5000
Buy at Done Right Safety

Done Right Safety Team

Safety, PPE & Workwear Specialists

Written from the product real specifications, its listed AS/NZS ratings and manufacturer supplied detail. Where a listing does not state a rating, the guide says so. Read the editorial standards.

Published 21 May 2026Last reviewed 5 June 2026

Sources

  • Pratt SE5000 product listing on donerightsafety.com.au
  • AS4775 (Standards Australia)
  • ANSI Z358.1 (American National Standards Institute)
Pratt gravity fed portable eyewash unit, 35LSE5000
Buy at the store
Compare 0
Compare these